The global impact of COVID-19 on our people and the global economy is significant, and Watlow has taken a comprehensive approach to deal with the current crisis. Our contingency planning includes protecting our team members, communicating often with our customers and partners and maintaining the continuity of supply lines.

At the beginning of the pandemic, we set two priorities that guide our responses and decisions: the health and safety of our team members while continuing to supply essential products needed by our customers.

If you have questions about how the pandemic is impacting Watlow or Watlow’s response, please contact your Watlow representative.

Total Application Support Solves Circulation Heater Request

Problem:

A large overseas engineering firm was contacted by a Korean petrochemical company to build an up-to-date processing plant. The requirements were a methane preheater to heat 155 pounds (70 kg) per hour of hydrogen from 50°F (10°C) to an outlet temperature of 645°F (340°C), at an operating pressure of 450 psig (65 kPa), with a maximum allowable pressure drop 10 psi (1.5 kPa)

Solution:

Watlow recommended a 6-inch (15 cm) circulation heater with 1-inch (25 mm) inlet, 1.5-inch (38 mm) outlet, 500 pound (226 kg) steel construction with fifteen 304 stainless steel elements designed for maximum 25 W/in2 (3.9 W/cm2) watt density. Additionally, the heater assembly had a NEMA 4 housing and Type K thermocouples for process and high-limit temperature control. The heater was designed at 101 kW, 3-phase, 440V, 60Hz.

In addition to the circulation heater, Watlow offered the complete control panel to run the 101 kW heater, which included a 150 ampere SCR, a SERIES 340 high-limit controller, a NEMA 4 enclosure with all necessary indicator lights, push button controls and main disconnect switches. The process controller on this particular control panel was supplied by the customer

Value Added:

Application expertise