WATROD™ Tubular Heaters
Fits Virtually Entire Range of Immersion and Air Heating Applications
-
Available in single- or double-ended termination styles, the versatile and economical WATROD tubular heating element from Watlow lends itself to virtually the entire range of immersion and air heating applications. The single-ended WATROD tubular heater design has both terminals at one end. The opposite end is sealed. Flexible lead wires are 12 in. (305 mm) crimp connected to the terminal pin and have silicone-impregnated fiberglass oversleeves. The double-ended WATROD, with its round cross-sectional geometry, are highly adaptable for bending—especially when bending is performed in the field. Watlow's double-ended MULTICOIL tubular elements offer various combinations of resistor coils and thermocouples inside one sheath. They have the ability to sense the heater's internal temperature accurately every time, or offer three-phase capability in one element. Both single- and double-ended WATRODs share many construction features delivering long life—the resistance wire is centered in the heater sheath and electrically insulated with compacted, high-grade magnesium oxide for superior heating performance. WATROD tubular heating elements have a variety of mounting and termination options making them highly popular among industrial customers.
-
Description Information Material Double-Ended Alloy 800/840 Maximum Operating Temperature - C 982 ºC Maximum Operating Temperature - F 1800 ºF Maximum Watt Densities 6.9 W/cm^2 Maximum Watt Densities 45 W/in^2 Description Information Material Double-Ended Stainless Steel Maximum Operating Temperature - C 175 ºC Maximum Operating Temperature - F 350 ºF Maximum Watt Densities 9.3 W/cm^2 Maximum Watt Densities 60 W/in^2 Description Information Material Double-Ended Steel Maximum Operating Temperature - C 400 ºC Maximum Operating Temperature - F 750 ºF Maximum Watt Densities 6.9 W/cm^2 Maximum Watt Densities 45 W/in^2 Description Information Material Singled-ended Alloy 800/840 Maximum Operating Temperature - C 870 ºC Maximum Operating Temperature - F 1600 ºF Maximum Watt Densities 6.9 W/cm^2 Maximum Watt Densities 45 W/in^2 Description Information Material Single-Ended Stainless Steel Maximum Operating Temperature - C 650 ºC Maximum Operating Temperature - F 1200 ºF Maximum Watt Densities 9.3 W/cm^2 Maximum Watt Densities 60 W/in^2 -
Downloads
Brochure
Catalog
Specification Sheet
User Manual
-
Available in single- or double-ended termination styles, the versatile and economical WATROD tubular heating element from Watlow lends itself to virtually the entire range of immersion and air heating applications.
The single-ended WATROD tubular heater design has both terminals at one end. The opposite end is sealed. Flexible lead wires are 12 in. (305 mm) crimp connected to the terminal pin and have silicone-impregnated fiberglass oversleeves.
The double-ended WATROD, with its round cross-sectional geometry, are highly adaptable for bending—especially when bending is performed in the field. Watlow's double-ended MULTICOIL tubular elements offer various combinations of resistor coils and thermocouples inside one sheath. They have the ability to sense the heater's internal temperature accurately every time, or offer three-phase capability in one element.
Both single- and double-ended WATRODs share many construction features delivering long life—the resistance wire is centered in the heater sheath and electrically insulated with compacted, high-grade magnesium oxide for superior heating performance.
WATROD tubular heating elements have a variety of mounting and termination options making them highly popular among industrial customers.
Description | Information |
---|---|
Material | Double-Ended Alloy 800/840 |
Maximum Operating Temperature - C | 982 ºC |
Maximum Operating Temperature - F | 1800 ºF |
Maximum Watt Densities | 6.9 W/cm^2 |
Maximum Watt Densities | 45 W/in^2 |
Description | Information |
---|---|
Material | Double-Ended Stainless Steel |
Maximum Operating Temperature - C | 175 ºC |
Maximum Operating Temperature - F | 350 ºF |
Maximum Watt Densities | 9.3 W/cm^2 |
Maximum Watt Densities | 60 W/in^2 |
Description | Information |
---|---|
Material | Double-Ended Steel |
Maximum Operating Temperature - C | 400 ºC |
Maximum Operating Temperature - F | 750 ºF |
Maximum Watt Densities | 6.9 W/cm^2 |
Maximum Watt Densities | 45 W/in^2 |
Description | Information |
---|---|
Material | Singled-ended Alloy 800/840 |
Maximum Operating Temperature - C | 870 ºC |
Maximum Operating Temperature - F | 1600 ºF |
Maximum Watt Densities | 6.9 W/cm^2 |
Maximum Watt Densities | 45 W/in^2 |
Description | Information |
---|---|
Material | Single-Ended Stainless Steel |
Maximum Operating Temperature - C | 650 ºC |
Maximum Operating Temperature - F | 1200 ºF |
Maximum Watt Densities | 9.3 W/cm^2 |
Maximum Watt Densities | 60 W/in^2 |
Downloads
Brochure
Catalog
Specification Sheet
User Manual