EZ-ZONE® RM High-Density Limit
The EZ-ZONE®RM high-density limit module used in conjunction with the EZ-ZONE RM temperature control module and high-density control module offer agency approved over and under temperature limit function to ensure system safety. The EZ-ZONE RM high-density limit controls 4, 8, or 12 limit loops per module or up to 192 limit loops per system.
Specifications:
| Max Limit Loops: |
192 |
| Max Monitor Channels: |
192 |
| Alarms: |
24 (per module) |
| Mounting: |
DIN-rail |
| Max Output: |
5A |
| Ambient Operating Range: |
-18 to 65°C
(0 to 149°F)
|
| Agency Approvals: |
UL® , CSA, CE, RoHS, W.E.E.E. FM, SEMI F47-0200 |
| Communication Protocols: |
Standard Bus, Modbus® RTU |
| Remote Limit Reset: |
Yes, if digital inputs are ordered |
| Display Height: |
Optional RUI: 0.84 in. (21 mm) |
| Warranty (years): |
3 |
Note: The specifications in the table above are best available values in each category. Not all combinations of these values are available in a single model number.
Features & Benefits:
| Features |
Benefits |
| 4 to 192 loop limit controller |
- Eliminates compatability issues often encountered with using many different discrete components and brands
- Saves engineering time and labor costs while shortening project schedules
- Allows a common limit controller platform across many
design applications
|
| Communications |
- Allows standard bus communications
- Ability to utilize EIA 485, Modbus® RTU options
|
| SPLIT-RAIL control |
- Minimizes the length and cost of wire runs and improves system reliability by locating inputs closer to sensors and outputs closer to loads
|
| SENSOR GUARD |
- Prevents unplanned process shutdowns and product loss by switching to a backup sensor if the primary sensor fails
|
| AUTO CLONE |
- Saves time and reduces complexity by automatically configuring a new module with the same parameter settings as the replaced module
|
Images:
EZ-ZONE RM Module
|
|
|